Medical Physics, AI and Neurotechnology · University of Rome Tor Vergata

fismed@uniroma2.it

FISMED / PEOPLE

Maria G. Guerrisi

Lecturer in Applied Physics · University of Rome Tor Vergata · UniCamillus

BACKGROUND

Biography

Maria Giovanna Guerrisi works in medical physics, with research spanning cardiovascular modelling, physiological measurement, biomedical signal analysis and the physical mechanisms of neurostimulation. She trained in physics at Sapienza University of Rome and developed experimental and computational approaches to circulatory function, cardiac assistance and the interpretation of biomedical measurements.

Her academic work includes extensive teaching of physics for medicine, dentistry and the health professions. She has held leadership and teaching coordination responsibilities in medical physics at Tor Vergata and contributed to specialist training in the discipline. Her recent teaching includes applied physics, radiation protection and biomechanics, alongside applied physics courses at UniCamillus.

RESEARCH & EXPERTISE

Research interests

  • Cardiovascular modelling
  • Physiological measurements
  • Biomedical signal analysis
  • Neurostimulation
  • Medical physics education

RESEARCH OUTPUT

Selected publications

  1. Multishell diffusion MRI reveals whole-brain white matter changes in HIV.Human brain mapping · 2023
    Diffusion tensor imaging (DTI) and diffusion kurtosis imaging (DKI) have been previously used to explore white matter related to human immunodeficiency virus (HIV) infection. While DTI and DKI suffer from low specificity, the Combined Hindered and Restricted Model of Diffusion (CHARMED) provides additional microstructural specificity. We used these three models to evaluate microstructural differences between 35 HIV-positive patients without neurological impairment and 20 healthy controls who underwent diffusion-weighted imaging using three b-values. While significant group effects were found in all diffusion metrics, CHARMED and DKI analyses uncovered wider involvement (80% vs. 20%) of all white matter tracts in HIV infection compared with DTI. In restricted fraction (FR) analysis, we found significant differences in the left corticospinal tract, middle cerebellar peduncle, right inferior cerebellar peduncle, right corticospinal tract, splenium of the corpus callosum, left superior cerebellar peduncle, left superior cerebellar peduncle, pontine crossing tract, left posterior limb of the internal capsule, and left/right medial lemniscus. These are involved in language, motor, equilibrium, behavior, and proprioception, supporting the functional integration that is frequently impaired in HIV-positivity. Additionally, we employed a machine learning algorithm (XGBoost) to discriminate HIV-positive patients from healthy controls using DTI and CHARMED metrics on an ROIwise basis, and unique contributions to this discrimination were examined using Shapley Explanation values. The CHARMED and DKI estimates produced the best performance. Our results suggest that biophysical multishell imaging, combining additional sensitivity and built-in specificity, provides further information about the brain microstructural changes in multimodal areas involved in attentive, emotional and memory networks often impaired in HIV patients.
  2. Clinical implementation of a log file-based machine and patient QA system for IMRT and VMAT treatment plans.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2023
    PURPOSE: To determine the error detection sensitivity of a commercial log file-based system (LINACWatch®, LW) for integration into clinical routine and to compare it with a measurement device (OCTAVIUS 4D, Oct4D) for IMRT and VMAT delivery QA. MATERIALS AND METHODS: 76 VMAT/IMRT plans (H&N, prostate, rectum and breast) preliminarily classified according to their Modulation Complexity Score (MCS) calculated by LW, were considered. Receiver Operating Characteristic (ROC) Curves were used to establish gamma criteria for LW. 12 plans (3 for each site) were intentionally modified in order to introduce delivery errors regarding MLC, jaws, collimator, gantry and MU (for a total set of 168 incorrect plans) and irradiated on Oct4D; the corresponding log files were analysed by LW. Each incorrect plan was compared to the error-free plan using γ-index analysis for MLC, jaws and MU errors investigation and Root-Mean-Square (RMS) values for gantry and collimator errors investigation. RESULTS: MCS ranges values were: 0.10-0.20 for H&N, 0.21-0.40 for prostate and rectum, 0.41-1.00 for breast. From ROC curves, the Gamma Passing Rate (GPR) thresholds were: 87%, 92%, 99% for H&N, prostate and rectum, and breast, respectively. The 1.5%/1.5 mm/local criteria were adopted for the γ-analysis. LW sensitivity in detecting the introduced errors was higher when compared to Oct4D: 48.5% vs 30.4% respectively. CONCLUSIONS: LW can be considered useful complement to phantom-based delivery QA of IMRT/VMAT plans. The MCS tool is effective in detecting over or under modulated plans prior to pre-treatment QA. However, rigorous and routinely machine QCs are recommended.
  3. Classification of real-world pathological phonocardiograms through multi-instance learning.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2021
    Heart auscultation is an inexpensive and fundamental technique to effectively to diagnose cardiovascular disease. However, due to relatively high human error rates even when auscultation is performed by an experienced physician, and due to the not universal availability of qualified personnel e.g. in developing countries, a large body of research is attempting to develop automated, computational tools for detecting abnormalities in heart sounds. The large heterogeneity of achievable data quality and devices, the variety o possible heart pathologies, and a generally poor signal-to-noise ratio make this problem extremely challenging. We present an accurate classification strategy for diagnosing heart sounds based on 1) automatic heart phase segmentation, 2) state-of-the art filters drawn from the filed of speech synthesis (mel-frequency cepstral representation), and 3) an ad-hoc multi-branch, multi-instance artificial neural network based on convolutional layers and fully connected neuronal ensembles which separately learns from each heart phase, hence leveraging their different physiological significance. We demonstrate that it is possible to train our architecture to reach very high performances, e.g. an AUC of 0.87 or a sensitivity of 0.97. Our machine-learning-based tool could be employed for heart sound classification, especially as a screening tool in a variety of situations including telemedicine applications.
  4. Compartmental models for diffusion weighted MRI reveal widespread brain changes in HIV-infected patients.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2021
    Diffusion tensor imaging (DTI) has been used to explore changes in the brain of subjects with human immunodeficiency virus (HIV) infection. However, DTI notoriously suffers from low specificity. Neurite orientation dispersion and density imaging (NODDI) is a compartmental model able to provide specific microstructural information with additional sensitivity/specificity. In this study we use both the NODDI and the DTI models to evaluate microstructural differences between 35 HIV-positive patients and 20 healthy controls. Diffusion-weighted imaging was acquired using three b-values (0, 1000 and 2500 s/mm2). Both DTI and NODDI models were fitted to the data, obtaining estimates for fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD), axial diffusivity (AD), neurite density index (NDI) and orientation dispersion index (ODI), after which we performed group comparisons using Tract-based spatial statistics (TBSS). While significant group effects were found in in FA, MD, RD, AD and NDI, NDI analysis uncovered a much wider involvement of brain tissue in HIV infection as compared to DTI. In region-of interest (ROI)-based analysis, NDI estimates from the right corticospinal tract produced excellent performance in discriminating the two groups (AUC = 0.974, sensitivity = 90%; specificity =97%).
  5. Comparison of rigid and deformable coregistration between mpMRI and CT images in radiotherapy of prostate bed cancer recurrence.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2021
    PURPOSE: To evaluate the accuracy of rigid coregistration between multiparametric magnetic resonance (mpMR) and computed tomography (CT) images for radiotherapy of prostate bed cancer recurrence. MATERIALS AND METHOD: Fifty-three patients (59 nodules) accrued in a prospective study on salvage radiotherapy for prostatic bed recurrence were suitable for the analysis. Patients underwent a pre radiotherapy mpMR exam and a planning CT in the same treatment position and with control of organ filling. The site of recurrence was delineated on mpMR images and contours transferred on planning CT images using both rigid and deformable registrations. Coregistrations were evaluated by mathematical operators that quantify deformation (Jacobian determinant and vector curl) and similarity indices (Dice and Jaccard coefficients). Dose coverage was evaluated. RESULTS: Deformable registration did not change volumes, (p = 0.92 MW test). The Jacobian coefficient and the vector curl revealed no important image deformations. Dice and Jaccard coefficients indicated dislocation of the nodule volumes. Dislocation magnitude was d = (5.6 ± 3.1) mm. Organ filling was not correlated with deformation or dislocation. Volumes were covered by the 95% isodose in 96% of cases when rigid registration was performed versus 75% of cases when deformed. CONCLUSIONS: Rigid image coregistration is sufficiently accurate in this setting. The results indicate that the deformable registration tends to shrink the voxels and to dislocate the ROI, the adopted expansion for the recurrence volume adequately accounts for the observed deformation and dislocation, provided that organ filling is controlled.

LABORATORIES & RESEARCH

Related research

EDUCATION & MENTORING

Teaching archive

Back to researchers and staff